400-0066-400

Human Histone Deacetylase 2 (HDAC2) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human Histone Deacetylase 2 (HDAC2) ELISA Kit
Product Name:

Human Histone Deacetylase 2 (HDAC2) ELISA Kit

Cat.#:

JL15510

Regulatory Status:
Alternative:

RPD3; YAF1; HD2

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.075ng/mL
Specificity:
This kit recognizes Human HDAC2 in samples. No significant cross-reactivity or interference between Human HDAC2 and analogues was observed.
Sample Type:
tissue homogenates, cell lysates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Cancer
  • Human Histone Deacetylase 2 (HDAC2) ELISA Kit
  • Human Histone Deacetylase 2 (HDAC2) ELISA Kit
  • Human Histone Deacetylase 2 (HDAC2) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| HDAC2

Histone deacetylase 2 (HDAC2) is an enzyme that is encoded by the HDAC2 gene. It belongs to the histone deacetylase class of enzymes responsible for the removal of acetyl groups from lysine residues at the N-terminal region of the core histones (H2A, H2B, H3, and H4). As such, it plays an important role in gene expression by facilitating the formation of transcription repressor complexes and for this reason is often considered an important target for cancer therapy.Though the functional role of the class to which HDAC2 belongs has been carefully studied, the mechanism by which HDAC2 interacts with histone deacetylases of other classes has yet to be elucidated.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 10 5 2.5 1.25 0.625 0.312 0.156 0
OD 2.6 1.9 1.24 0.75 0.46 0.31 0.22 0.07
Corrected OD 2.53 1.83 1.17 0.68 0.39 0.24 0.15 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human HDAC2 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Tissue Homogenates(n=8) 94-105 102
Cell Lysates(n=8) 96-108 103





 

| Linearity

Samples were spiked with high concentrations of Human HDAC2 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Tissue Homogenates(n=4) Cell Lysates(n=4)
1 : 2 Range (%) 86-96 90-110
Average (%) 93 95
1 : 4 Range (%) 87-108 105-115
Average (%) 98 109







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
360 / 360
96T
1
460 / 460