Product Name:
Human Transcription factor Sp7 (SP7) ELISA Kit
Cat.#:
JL15982
Regulatory Status:
Alternative:
OSX;Sp7 Transcription Factor; Specificity Protein 7; Zinc finger protein osterix
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.073ng/mL
Specificity:
This kit recognizes Human SP7 in samples. No significant cross-reactivity or interference between Human SP7 and analogues was observed.
Sample Type:
Tissue homogenates, cell lysates and other biological fluids
Assay Procedure:

Research Area:
Signal Transduction
Product Datasheets
| SP7
Transcription factor Sp7, also called Osterix (Osx), is a protein that is encoded by the SP7 gene. It is a member of the Sp family of zinc-finger transcription factors It is highly conserved among bone-forming vertebrate species It plays a major role, along with Runx2 and Dlx5 in driving the differentiation of mesenchymal precursor cells into osteoblasts and eventually osteocytes.[8] Sp7 also plays a regulatory role by inhibiting chondrocyte differentiation maintaining the balance between differentiation of mesenchymal precursor cells into ossified bone or cartilage.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0.156 | 0 |
OD | 2.6 | 1.51 | 0.78 | 0.46 | 0.32 | 0.24 | 0.2 | 0.09 |
Corrected OD | 2.51 | 1.42 | 0.69 | 0.37 | 0.23 | 0.15 | 0.11 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human SP7 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Tissue Homogenates(n=8) | 90-105 | 102 |
Cell Culture Supernates(n=8) | 96-108 | 103 |
| Linearity
Samples were spiked with high concentrations of Human SP7 and diluted with Universal Diluent to produce samples with values within the range of the assay.Tissue Homogenates(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 88-96 | 92-110 |
Average (%) | 93 | 96 | |
1 : 4 | Range (%) | 87-108 | 105-115 |
Average (%) | 99 | 108 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460