Product Name:
Human Interferon Regulatory Factor 5 (IRF5) ELISA Kit
Cat.#:
JL19415
Regulatory Status:
Alternative:
Interferon Regulatory Factor 5
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.15-10ng/mL
Sensitivity:
0.06ng/mL
Specificity:
This kit recognizes Human IRF5 in samples. No significant cross-reactivity or interference between Human IRF5 and analogues was observed.
Sample Type:
serum, plasma, tissue homogenates and other biological fluids
Assay Procedure:

Research Area:
Signal Transduction
Product Datasheets
| IRF5
Interferon regulatory factor 5 is a protein that is encoded by the IRF5 gene. The IRF family is a group of transcription factors that are involved in signaling for virus responses in mammals along with regulation of certain cellular functions.IRF5 is a member of the interferon regulatory factor (IRF) family, a group of transcription factors with diverse roles, including virus-mediated activation of interferon, and modulation of cell growth, differentiation, apoptosis, and immune system activity. Members of the IRF family are characterized by a conserved N-terminal DNA-binding domain containing tryptophan (W) repeats. Alternative splice variants encoding different isoforms exist.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0.15 | 0 |
OD | 1.99 | 1.26 | 0.82 | 0.52 | 0.37 | 0.27 | 0.22 | 0.08 |
Corrected OD | 1.91 | 1.18 | 0.74 | 0.44 | 0.29 | 0.19 | 0.14 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human IRF5 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 84-101 | 96 |
Plasma(n=8) | 92-104 | 101 |
Tissue Homogenates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human IRF5 and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | Tissue Homogenates(n=4) | ||
1 : 2 | Range (%) | 84-96 | 88-96 | 90-110 |
Average (%) | 92 | 93 | 96 | |
1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
Average (%) | 94 | 97 | 108 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460