Product Name:
Human Telomeric Repeat Binding Factor 2 (TERF2) ELISA Kit
Cat.#:
JL14629
Regulatory Status:
Alternative:
TRBF2; TRF2; TTAGGG repeat-binding factor 2; Telomeric DNA-binding protein
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.075ng/mL
Specificity:
This kit recognizes Human TERF2 in samples. No significant cross-reactivity or interference between Human TERF2 and analogues was observed.
Sample Type:
Tissue homogenates, cell lysates and other biological fluids
Assay Procedure:

Research Area:
Signal Transduction
Product Datasheets
| TERF2
Telomeric repeat-binding factor 2 is a protein that is present at telomeres throughout the cell cycle. It is also known as TERF2, TRF2, and TRBF2, and is encoded in humans by the TERF2 gene. It is a component of the shelterin nucleoprotein complex and a second negative regulator of telomere length, playing a key role in the protective activity of telomeres. It was first reported in 1997 in the lab of Titia de Lange, where a DNA sequence similar, but not identical, to TERF1 was discovered, with respect to the Myb-domain. De Lange isolated the new Myb-containing protein sequence and called it TERF2.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0.156 | 0 |
OD | 2.25 | 1.64 | 1.08 | 0.71 | 0.46 | 0.33 | 0.25 | 0.08 |
Corrected OD | 2.17 | 1.56 | 1 | 0.63 | 0.38 | 0.25 | 0.17 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human TERF2 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Tissue Homogenates(n=8) | 89-105 | 102 |
Cell Culture Supernates(n=8) | 96-108 | 104 |
| Linearity
Samples were spiked with high concentrations of Human TERF2 and diluted with Universal Diluent to produce samples with values within the range of the assay.Tissue Homogenates(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 88-98 | 90-110 |
Average (%) | 93 | 98 | |
1 : 4 | Range (%) | 87-108 | 105-115 |
Average (%) | 98 | 108 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460