Product Name:
Human Podocin (PDCN) ELISA Kit
Cat.#:
JL52512
Regulatory Status:
Alternative:
NPHS2; NPHS-2; Nephrosis 2; Idiopathic Steroid-Resistant
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.78-50ng/mL
Sensitivity:
0.36ng/mL
Specificity:
This kit recognizes Human PDCN in samples. No significant cross-reactivity or interference between Human PDCN and analogues was observed.
Sample Type:
Tissue homogenates, urine, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:

Research Area:
Cell Biology
Product Datasheets
| PDCN
Podocin is a protein component of the filtration slits of podocytes. Glomerular capillary endothelial cells, the glomerular basement membrane and the filtration slits function as the filtration barrier of the kidney glomerulus. Mutations in the podocin gene NPHS2 can cause nephrotic syndrome, such as focal segmental glomerulosclerosis (FSGS) or minimal change disease (MCD). Symptoms may develop in the first few months of life (congenital nephrotic syndrome) or later in childhood.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (ng/mL) | 50 | 25 | 12.5 | 6.25 | 3.12 | 1.56 | 0.78 | 0 |
OD | 2.18 | 1.57 | 1.03 | 0.62 | 0.42 | 0.32 | 0.26 | 0.1 |
Corrected OD | 2.08 | 1.47 | 0.93 | 0.52 | 0.32 | 0.22 | 0.16 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human PDCN spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Cell Lysates(n=8) | 84-101 | 96 |
Tissue Homogenates(n=8) | 92-105 | 102 |
Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human PDCN and diluted with Universal Diluent to produce samples with values within the range of the assay.Cell Lysates(n=4) | Tissue Homogenates(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
Average (%) | 90 | 93 | 96 | |
1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
Average (%) | 94 | 98 | 108 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460