400-0066-400

Human Ubiquitin-like 1-activating enzyme E1B (UBA2) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human Ubiquitin-like 1-activating enzyme E1B (UBA2) ELISA Kit
Product Name:

Human Ubiquitin-like 1-activating enzyme E1B (UBA2) ELISA Kit

Cat.#:

JL17959

Regulatory Status:
Alternative:

UBLE1B;SAE2; ARX; SUMO1 Activating Enzyme Subunit 2; Anthracycline-associated resistance ARX; Ubiquitin Like Modifier Activating Enzyme 2; SUMO-activating enzyme subunit 2

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.07ng/mL
Specificity:
This kit recognizes Human UBA2 in samples. No significant cross-reactivity or interference between Human UBA2 and analogues was observed.
Sample Type:
tissue homogenates, cell lysates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Cell Biology
  • Human Ubiquitin-like 1-activating enzyme E1B (UBA2) ELISA Kit
  • Human Ubiquitin-like 1-activating enzyme E1B (UBA2) ELISA Kit
  • Human Ubiquitin-like 1-activating enzyme E1B (UBA2) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| UBA2

Ubiquitin-like 1-activating enzyme E1B (UBLE1B) also known as SUMO-activating enzyme subunit 2 (SAE2) is an enzyme that is encoded by the UBA2 gene.Posttranslational modification of proteins by the addition of the small protein SUMO (see SUMO1), or sumoylation, regulates protein structure and intracellular localization. SAE1 and UBA2 form a heterodimer that functions as a SUMO-activating enzyme for the sumoylation of proteins.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 10 5 2.5 1.25 0.625 0.312 0.156 0
OD 2.36 1.7 1.26 0.87 0.6 0.4 0.28 0.09
Corrected OD 2.27 1.61 1.17 0.78 0.51 0.31 0.19 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human UBA2 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Tissue Homogenates(n=8) 89-105 102
Cell Lysates(n=8) 96-108 104





 

| Linearity

Samples were spiked with high concentrations of Human UBA2 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Tissue Homogenates(n=4) Cell Lysates(n=4)
1 : 2 Range (%) 85-96 90-110
Average (%) 93 96
1 : 4 Range (%) 87-108 105-115
Average (%) 98 109







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
360 / 360
96T
1
460 / 460