Product Name:
Human UDP-Glucose Glycoprotein Glucosyltransferase 1 (UGGT) ELISA Kit
Cat.#:
JL15006
Regulatory Status:
Alternative:
UGTR; HUGT1; GT; UGCGL1; UGGT; UGT1; UDP-glucose ceramide glucosyltransferase-like 1;UDP-Glucose Glycoprotein Glucosyltransferase 1
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.312-20ng/mL
Sensitivity:
0.152ng/mL
Specificity:
This kit recognizes Human UGGT in samples. No significant cross-reactivity or interference between Human UGGT and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:

Research Area:
Cell Biology
Product Datasheets
| UGGT
UGGT, or UDP-glucose:glycoprotein glucosyltransferase, is a soluble enzyme resident in the lumen of the endoplasmic reticulum (ER).The main function of UGGT is to recognize misfolded glycoproteins and transfer a glucose (Glc) monomer (monoglucosylate) to the terminal mannose of the A-branch of the glycan on the glycoprotein. UGGT is about 170 kDa and it consists of two structurally independent portions: a variable N-terminal portion of ~1200 amino acids, which in turn comprises 4 thioredoxin-like domains and two beta-sandwich domains, and senses glycoprotein misfolding; and a highly conserved C-terminal catalytic portion of ~300 amino acids, folding as a glucosyltransferase domain belonging to fold family GT24.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (ng/mL) | 20 | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0 |
OD | 2.68 | 1.74 | 1.01 | 0.67 | 0.41 | 0.28 | 0.2 | 0.09 |
Corrected OD | 2.59 | 1.65 | 0.92 | 0.58 | 0.32 | 0.19 | 0.11 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human UGGT spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Tissue Homogenates(n=8) | 92-106 | 102 |
Cell Culture Supernates(n=8) | 96-108 | 104 |
| Linearity
Samples were spiked with high concentrations of Human UGGT and diluted with Universal Diluent to produce samples with values within the range of the assay.Tissue Homogenates(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 88-96 | 90-110 |
Average (%) | 92 | 96 | |
1 : 4 | Range (%) | 87-108 | 103-115 |
Average (%) | 98 | 108 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460