Human Tumor Necrosis Factor Ligand Superfamily, Member 13 (TNFSF13) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human Tumor Necrosis Factor Ligand Superfamily, Member 13 (TNFSF13) ELISA Kit
Product Name:

Human Tumor Necrosis Factor Ligand Superfamily, Member 13 (TNFSF13) ELISA Kit

Cat.#:

JL29691

Regulatory Status:
Alternative:

CD256; APRIL; TALL2; TRDL1; ZTNF2; A Proliferation Inducing Ligand; TNF And APOL Related Leukocyte Expressed Ligand 2; TNF-Related Death Ligand 1

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
46.87-3000pg/mL
Sensitivity:
16.66pg/mL
Specificity:
This kit recognizes Human TNFSF13 in samples. No significant cross-reactivity or interference between Human TNFSF13 and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Cancer
  • Human Tumor Necrosis Factor Ligand Superfamily, Member 13 (TNFSF13) ELISA Kit
  • Human Tumor Necrosis Factor Ligand Superfamily, Member 13 (TNFSF13) ELISA Kit
  • Human Tumor Necrosis Factor Ligand Superfamily, Member 13 (TNFSF13) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| TNFSF13

A proliferation-inducing ligand (APRIL), also known as tumor necrosis factor ligand superfamily member 13 (TNFSF13), is a protein of the TNF superfamily recognized by the cell surface receptor TACI. It is encoded by the TNFSF13 gene.The protein encoded by this gene is a member of the tumor necrosis factor ligand (TNF) ligand family. This protein is a ligand for TNFRSF17/BCMA, a member of the TNF receptor family. This protein and its receptor are both found to be important for B cell development. In vivo experiments suggest an important role for APRIL in the long-term survival of plasma cells in the bone marrow. Mice deficient in APRIL have normal immune system development.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (pg/mL) 3000 1500 750 375 187.5 93.7 46.8 0
OD 2.35 1.35 0.8 0.48 0.34 0.26 0.22 0.09
Corrected OD 2.26 1.26 0.71 0.39 0.25 0.17 0.13 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human TNFSF13 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-105 102
Tissue Homogenates(n=8) 96-108 105





 

| Linearity

Samples were spiked with high concentrations of Human TNFSF13 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Tissue Homogenates(n=4)
1 : 2 Range (%) 84-95 88-96 89-110
Average (%) 91 93 96
1 : 4 Range (%) 89-103 87-108 105-115
Average (%) 94 98 108







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
420 / 420
96T
1
640 / 640
Top