Product Name:
Human Prostaglandin E Synthase, Microsomal (PTGES) ELISA Kit
Cat.#:
JL42724
Regulatory Status:
Alternative:
MGST1L1; MGST-IV; MGST1-L1; PGES; PIG12; PP102; PP1294; TP53I12; PGE Synthase; Tumor Protein p53 Inducible Protein 12; Glutathione S-Transferase 1-Like 1; MGST1-Like 1
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
1.56-100ng/mL
Sensitivity:
0.76ng/mL
Specificity:
This kit recognizes Human PTGES in samples. No significant cross-reactivity or interference between Human PTGES and analogues was observed.
Sample Type:
Tissue homogenates, cell lysates and other biological fluids
Assay Procedure:

Research Area:
Cell Biology
Product Datasheets
| PTGES
Microsomal prostaglandin E synthase-1 (mPGES-1) or Prostaglandin E synthase is an enzyme that is encoded by the PTGES gene.The protein encoded by this gene is a glutathione-dependent prostaglandin E synthase. The expression of this gene has been shown to be induced by proinflammatory cytokine interleukin 1 beta (IL1B). Its expression can also be induced by tumor suppressor protein TP53, and may be involved in TP53-induced apoptosis.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (ng/mL) | 100 | 50 | 25 | 12.5 | 6.25 | 3.12 | 1.56 | 0 |
OD | 2.67 | 2.05 | 1.48 | 0.97 | 0.67 | 0.42 | 0.27 | 0.09 |
Corrected OD | 2.58 | 1.96 | 1.39 | 0.88 | 0.58 | 0.33 | 0.18 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human PTGES spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Tissue Homogenates(n=8) | 92-105 | 102 |
Cell Lysates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human PTGES and diluted with Universal Diluent to produce samples with values within the range of the assay.Tissue Homogenates(n=4) | Cell Lysates(n=4) | ||
1 : 2 | Range (%) | 88-96 | 90-110 |
Average (%) | 93 | 96 | |
1 : 4 | Range (%) | 87-108 | 105-115 |
Average (%) | 98 | 108 |






Size
Quantity
Price ($)
48T


420 / 420
96T


640 / 640