400-0066-400

Human Mucin 7, Secreted (MUC7) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human Mucin 7, Secreted (MUC7) ELISA Kit
Product Name:

Human Mucin 7, Secreted (MUC7) ELISA Kit

Cat.#:

JL44662

Regulatory Status:
Alternative:

MG2; Mucin 7,Salivary; Apo-MG2; Salivary mucin-7

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.31-20ng/mL
Sensitivity:
0.2ng/mL
Specificity:
This kit recognizes Human MUC7 in samples. No significant cross-reactivity or interference between Human MUC7 and analogues was observed.
Sample Type:
Saliva, tissue homogenates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Signal Transduction
  • Human Mucin 7, Secreted (MUC7) ELISA Kit
  • Human Mucin 7, Secreted (MUC7) ELISA Kit
  • Human Mucin 7, Secreted (MUC7) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| MUC7

Mucin-7 is a protein that is encoded by the MUC7 gene.[3][4] In animals, the MUC7 gene is found in most placental mammals, but not marsupials.Humans carry either a five or six tandem repeat version of the gene. In other primates, the number of repeats found is 4-5 for gorillas, 5 for chimpanzees, 6-7 for orangutans, 8-10 for macaques, 10-11 for baboons and 11-12 for green monkeys.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 20 10 5 2.5 1.25 0.62 0.31 0
OD 2.28 1.24 0.67 0.35 0.19 0.14 0.11 0.09
Corrected OD 2.19 1.15 0.58 0.26 0.1 0.05 0.02 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human MUC7 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Saliva(n=8) 84-101 96
Tissue Homogenates(n=8) 92-105 102





 

| Linearity

Samples were spiked with high concentrations of Human MUC7 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Saliva(n=4) Tissue Homogenates(n=4)
1 : 2 Range (%) 85-95 88-96
Average (%) 91 93
1 : 4 Range (%) 89-103 87-108
Average (%) 94 98







 