Product Name:
Human Amylase Alpha 1, Salivary (AMY1) ELISA Kit
Cat.#:
JL19200
Regulatory Status:
Alternative:
AMY1; AMY1B; AMY1C; Ptyalin; 1,4-alpha-D-glucan glucanohydrolase 1
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
6.25-400ng/mL
Sensitivity:
2.32ng/mL
Specificity:
This kit recognizes Human AMY1 in samples. No significant cross-reactivity or interference between Human AMY1 and analogues was observed.
Sample Type:
Serum, plasma, saliva and other biological fluids
Assay Procedure:

Research Area:
Metabolism
Product Datasheets
| AMY1
Amylase Alpha 1, Salivary (AMY1) is an enzyme present in many organisms that is an isoenzyme of a amylase produced by the salivary glands. Amylases are enzymes that hydrolyze or breakdown starch into oligosaccharides such as dextrin and maltose. a-Amylase, a major protein in saliva, catalyzes the hydrolysis of 1, 4-á-glucosidic linkages in starch and other polysaccharides leading to the formation of smaller oligosaccharides, dextrins and maltoses. The enzyme also plays an important role in the colonization and metabolism of bacteria leading to the formation of dental plaque.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (ng/mL) | 400 | 200 | 100 | 50 | 25 | 12.5 | 6.25 | 0 |
OD | 2.15 | 1.63 | 1.13 | 0.71 | 0.5 | 0.33 | 0.23 | 0.07 |
Corrected OD | 2.08 | 1.56 | 1.06 | 0.64 | 0.43 | 0.26 | 0.16 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human AMY1 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 84-101 | 96 |
Plasma(n=8) | 92-105 | 102 |
Saliva(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human AMY1 and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | Saliva(n=4) | ||
1 : 2 | Range (%) | 84-95 | 88-96 | 90-111 |
Average (%) | 91 | 93 | 96 | |
1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
Average (%) | 94 | 98 | 108 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460