Product Name:
Human Diamine Oxidase (DAO) ELISA Kit
Cat.#:
JL10437
Regulatory Status:
Alternative:
AOC1; DAO; KAO; Histaminase; Kidney amine oxidase; Diamine Oxidase; Amiloride-sensitive amine oxidase; Amine oxidase copper domain-containing protein 1
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.31-20ng/mL
Sensitivity:
0.12ng/mL
Specificity:
This kit recognizes Human DAO in samples. No significant cross-reactivity or interference between Human DAO and analogues was observed.
Sample Type:
serum, plasma, tissue homogenates and other biological fluids
Assay Procedure:

Research Area:
Metabolism
Product Datasheets
| DAO
Diamine oxidase (DAO), also known "amine oxidase, copper-containing, 1" (AOC1), is an enzyme involved in the metabolism, oxidation, and inactivation of histamine and other polyamines such as putrescine or spermidine. The enzyme belongs to the amine oxidase (copper-containing) (AOC) family of amine oxidase enzymes. DAO is involved in the physiology of digestion and other physiological processes, such as inflammation, immune response, and wound healing. Dysfunction of DAO has been associated with various diseases, including allergies, autoimmune disorders, and cancer. DAO also plays a role in healthy pregnancy in placental mammals.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (ng/mL) | 20 | 10 | 5 | 2.5 | 1.25 | 0.62 | 0.31 | 0 |
OD | 2.45 | 1.46 | 0.89 | 0.57 | 0.39 | 0.28 | 0.23 | 0.09 |
Corrected OD | 2.36 | 1.37 | 0.8 | 0.48 | 0.3 | 0.19 | 0.14 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human DAO spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 84-101 | 96 |
Plasma(n=8) | 92-105 | 102 |
Tissue Homogenates(n=8) | 96-108 | 104 |
| Linearity
Samples were spiked with high concentrations of Human DAO and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | Tissue Homogenates(n=4) | ||
1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
Average (%) | 91 | 93 | 96 | |
1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
Average (%) | 94 | 98 | 108 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460