400-0066-400

Human Coagulation Factor II (FII) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human Coagulation Factor II (FII) ELISA Kit
Product Name:

Human Coagulation Factor II (FII) ELISA Kit

Cat.#:

JL46041

Regulatory Status:
Alternative:

F2; TM; PT; Thrombin; Prothrombin; Pro-Thrombin; Activation peptide fragment 1; Activation peptide fragment 2

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.46-30ng/mL
Sensitivity:
0.15ng/mL
Specificity:
This kit recognizes Human FII in samples. No significant cross-reactivity or interference between Human FII and analogues was observed.
Sample Type:
Serum
Assay Procedure:
Assay Procedure
Research Area:
Metabolism
  • Human Coagulation Factor II (FII) ELISA Kit
  • Human Coagulation Factor II (FII) ELISA Kit
  • Human Coagulation Factor II (FII) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| FII

Prothrombin (coagulation factor II) is encoded by the F2-gene. It is proteolytically cleaved during the clotting process by the prothrombinase enzyme complex to form thrombin. The molecular weight of prothrombin is approximately 72, Da. Structurally, it is a member of the large PA clan of proteases. Thrombin, a potent vasoconstrictor and mitogen, is implicated as a major factor in vasospasm following subarachnoid hemorrhage. Beyond its key role in the dynamic process of thrombus formation, thrombin has a pronounced pro-inflammatory character, which may influence the onset and progression of atherosclerosis.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 30 15 7.5 3.75 1.87 0.93 0.46 0
OD 2.3 1.65 1.06 0.56 0.29 0.17 0.11 0.05
Corrected OD 2.25 1.6 1.01 0.51 0.24 0.12 0.06 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human FII spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 90-105 101





 

| Linearity

Samples were spiked with high concentrations of Human FII and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4)
1 : 2 Range (%) 88-98
Average (%) 94
1 : 4 Range (%) 87-107
Average (%) 98







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
360 / 360
96T
1
460 / 460
Top