400-0066-400

Human Protectin (PT) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human Protectin (PT) ELISA Kit
Product Name:

Human Protectin (PT) ELISA Kit

Cat.#:

JL24294

Regulatory Status:
Alternative:

Protectin; MIC11; MIN1; MIN2; MIN3; MSK21; MAC-IP; MACIF; MIRL; HRF20; Complement Regulatory Protein; 20 kDa homologous restriction factor; Membrane attack complex inhibition factor

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
31.25-2000pg/mL
Sensitivity:
12.65pg/mL
Specificity:
This kit recognizes Human PTin samples. No significant cross-reactivity or interference between Human PT and analogues was observed.
Sample Type:
Serum, plasma, cell lysates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Cell Biology
  • Human Protectin (PT) ELISA Kit
  • Human Protectin (PT) ELISA Kit
  • Human Protectin (PT) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| PT

CD59 glycoprotein, also known as MAC-inhibitory protein (MAC-IP), membrane inhibitor of reactive lysis (MIRL), or protectin, is a protein that in humans is encoded by the CD59 gene.It is an LU domain and belongs to the LY6/uPAR/alpha-neurotoxin protein family.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (pg/mL) 2000 1000 500 250 125 62.5 31.25 0
OD 2.28 1.85 1.23 0.8 0.53 0.39 0.3 0.08
Corrected OD 2.2 1.77 1.15 0.72 0.45 0.31 0.22 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human PT spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-102 96
Plasma(n=8) 92-106 103
Cell Lysates(n=8) 96-108 105





 

| Linearity

Samples were spiked with high concentrations of Human PT and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Cell Lysates(n=4)
1 : 2 Range (%) 84-95 88-97 90-110
Average (%) 91 93 96
1 : 4 Range (%) 89-103 87-108 105-114
Average (%) 94 98 107







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
420 / 420
96T
1
640 / 640
Top