Product Name:
Human Cluster Of Differentiation 4 (CD4) ELISA Kit
Cat.#:
JL14306
Regulatory Status:
Alternative:
CD4mut; p55; T-cell surface glycoprotein CD4; T-cell surface antigen T4/Leu-3
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.31-20ng/mL
Sensitivity:
0.11ng/mL
Specificity:
This kit recognizes Human CD4in samples. No significant cross-reactivity or interference between Human CD4 and analogues was observed.
Sample Type:
tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:

Research Area:
Cell Biology
Product Datasheets
| CD4
In molecular biology, CD4 (cluster of differentiation 4) is a glycoprotein that serves as a co-receptor for the T-cell receptor (TCR). CD4 is found on the surface of immune cells such as helper T cells, monocytes, macrophages, and dendritic cells. It was discovered in the late 1970s and was originally known as leu-3 and T4 (after the OKT4 monoclonal antibody that reacted with it) before being named CD4 in 1984.[5] In humans, the CD4 protein is encoded by the CD4 gene.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (ng/mL) | 20 | 10 | 5 | 2.5 | 1.25 | 0.62 | 0.31 | 0 |
OD | 2.22 | 1.43 | 0.87 | 0.52 | 0.34 | 0.27 | 0.22 | 0.08 |
Corrected OD | 2.14 | 1.35 | 0.79 | 0.44 | 0.26 | 0.19 | 0.14 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human CD4 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Tissue Homogenates(n=8) | 92-105 | 102 |
Cell Lysates(n=8) | 92-106 | 102 |
Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human CD4 and diluted with Universal Diluent to produce samples with values within the range of the assay.Tissue Homogenates(n=4) | Cell Lysates(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 88-96 | 88-96 | 90-110 |
Average (%) | 92 | 93 | 96 | |
1 : 4 | Range (%) | 87-108 | 87-108 | 105-115 |
Average (%) | 98 | 98 | 108 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460