Product Name:
Human Cyclophilin of 40 kDa (CYP-40) ELISA Kit
Cat.#:
JL17001
Regulatory Status:
Alternative:
CYP-40; CYPD; CyP-D; PPIase D; Cyclophilin D; Cyclophilin 40; 40 kDa peptidyl-prolyl cis-trans isomerase; Cyclophilin-related protein; Rotamase D
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.312-20ng/mL
Sensitivity:
0.16ng/mL
Specificity:
This kit recognizes Human CYP-40 in samples. No significant cross-reactivity or interference between Human CYP-40 and analogues was observed.
Sample Type:
tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:

Research Area:
Signal Transduction
Product Datasheets
| CYP-40
Peptidylprolyl isomerase D (cyclophilin D), also known as PPID, is an enzyme which is encoded by the PPID gene on chromosome 4. As a member of the peptidyl-prolyl cis-trans isomerase (PPIase) family, this protein catalyzes the cis-trans isomerization of proline imidic peptide bonds, which allows it to facilitate folding or repair of proteins.[5] In addition, PPID participates in many biological processes, including mitochondrial metabolism, apoptosis, redox, and inflammation, as well as in related diseases and conditions, such as ischemic reperfusion injury, AIDS, and cancer.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (ng/mL) | 20 | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0 |
OD | 2.28 | 1.91 | 1.43 | 0.97 | 0.62 | 0.38 | 0.22 | 0.07 |
Corrected OD | 2.21 | 1.84 | 1.36 | 0.9 | 0.55 | 0.31 | 0.15 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human CYP-40 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Tissue Homogenates(n=8) | 83-101 | 96 |
Cell Lysates(n=8) | 92-105 | 102 |
Cell Culture Supernates(n=8) | 96-108 | 103 |
| Linearity
Samples were spiked with high concentrations of Human CYP-40 and diluted with Universal Diluent to produce samples with values within the range of the assay.Tissue Homogenates(n=4) | Cell Lysates(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 84-96 | 86-96 | 90-110 |
Average (%) | 91 | 93 | 96 | |
1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
Average (%) | 94 | 99 | 108 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460