Product Name:
Human A Disintegrin And Metalloprotease 8 (ADAM8) ELISA Kit
Cat.#:
JL10089
Regulatory Status:
Alternative:
CD156-A; MS2; CD156a; Disintegrin and metalloproteinase domain-containing protein 8
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
62.5-4000pg/mL
Sensitivity:
19.37pg/mL
Specificity:
This kit recognizes Human ADAM8 in samples. No significant cross-reactivity or interference between Human ADAM8 and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates and other biological fluids
Assay Procedure:

Research Area:
Immunology
Product Datasheets
| ADAM8
A Disintegrin and metalloproteinase domain-containing protein 8 is an enzyme encoded by the ADAM8 gene. This gene encodes a member of the ADAM (a disintegrin and metalloproteinase domain) family. Members of this family are membrane-anchored proteins structurally related to snake venom disintegrins, and have been implicated in a variety of biological processes involving cell–cell and cell-matrix interactions, including fertilization, muscle development, and neurogenesis. The protein encoded by this gene may be involved in cell adhesion during neurodegeneration.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (pg/mL) | 4000 | 2000 | 1000 | 500 | 250 | 125 | 62.5 | 0 |
OD | 2.58 | 1.59 | 0.93 | 0.55 | 0.37 | 0.28 | 0.21 | 0.09 |
Corrected OD | 2.49 | 1.5 | 0.84 | 0.46 | 0.28 | 0.19 | 0.12 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human ADAM8 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 84-101 | 96 |
Plasma(n=8) | 92-106 | 102 |
Cell Lysates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human ADAM8 and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | Cell Lysates(n=4) | ||
1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
Average (%) | 91 | 93 | 96 | |
1 : 4 | Range (%) | 89-102 | 87-108 | 105-115 |
Average (%) | 94 | 98 | 108 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460