400-0066-400

Human Mannose Associated Serine Protease 2 (MASP-2) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human Mannose Associated Serine Protease 2 (MASP-2) ELISA Kit
Product Name:

Human Mannose Associated Serine Protease 2 (MASP-2) ELISA Kit

Cat.#:

JL19404

Regulatory Status:
Alternative:

Mannose-binding protein-associated serine protease 2; mannan-Binding Lectin Serine Peptidase 2; MBL-associated serine protease 2

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
31.25-2000pg/mL
Sensitivity:
14.06pg/mL
Specificity:
This kit recognizes Human MASP-2 in samples. No significant cross-reactivity or interference between Human MASP-2 and analogues was observed.
Sample Type:
serum, plasma and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Immunology
  • Human Mannose Associated Serine Protease 2 (MASP-2) ELISA Kit
  • Human Mannose Associated Serine Protease 2 (MASP-2) ELISA Kit
  • Human Mannose Associated Serine Protease 2 (MASP-2) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| MASP-2

Mannose Associated Serine Protease 2 (MASP2) is an enzyme encoded by the MASP2 gene. The encoded protein is a member of the trypsin family. This mannan-binding lectin (MBL) recognizes patterns of neutral carbohydrates, such as mannose and N-acetylglucosamine. Ra-response factor (RARF) is a complement-dependent bactericidal factor that binds to Ra and R2 polysaccharides expressed by certain gut bacteria. Alternate splicing of this gene produces two transcriptional variants encoding two RARF components involved in the complement activated mannan pathway.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (pg/mL) 2000 1000 500 250 125 62.5 31.25 0
OD 2.38 1.47 0.84 0.48 0.32 0.25 0.2 0.09
Corrected OD 2.29 1.38 0.75 0.39 0.23 0.16 0.11 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human MASP-2 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-105 102





 

| Linearity

Samples were spiked with high concentrations of Human MASP-2 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4)
1 : 2 Range (%) 84-95 88-96
Average (%) 91 93
1 : 4 Range (%) 89-103 87-107
Average (%) 94 98







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
360 / 360
96T
1
460 / 460
Top