Product Name:
Human Erythropoietin (EPO) ELISA Kit
Cat.#:
JL13539
Regulatory Status:
Alternative:
EP; Epoetin; Erythropoetin; Hematopoietin; Hemopoietin
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
6.25-400mIU/mL
Sensitivity:
2.36mIU/mL
Specificity:
This kit recognizes Human EPO in samples. No significant cross-reactivity or interference between Human EPO and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:

Research Area:
Immunology
Product Datasheets
| EPO
Erythropoietin (EPO), also known as erythropoetin, haematopoietin, or haemopoietin, is a glycoprotein cytokine secreted mainly by the kidneys in response to cellular hypoxia.It stimulates red blood cell production (erythropoiesis) in the bone marrow. Low levels of EPO are constantly secreted in sufficient quantities to compensate for normal red blood cell turnover. Common causes of cellular hypoxia resulting in elevated levels of EPO include any anemia, and hypoxemia due to chronic lung disease and mouth disease.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (mIU/mL) | 400 | 200 | 100 | 50 | 25 | 12.5 | 6.25 | 0 |
OD | 2.31 | 1.52 | 1.01 | 0.63 | 0.44 | 0.32 | 0.24 | 0.09 |
Corrected OD | 2.22 | 1.43 | 0.92 | 0.54 | 0.35 | 0.23 | 0.15 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human EPO spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 85-101 | 96 |
Plasma(n=8) | 92-105 | 102 |
Cell Culture Supernates(n=8) | 96-108 | 104 |
| Linearity
Samples were spiked with high concentrations of Human EPO and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
Average (%) | 91 | 93 | 96 | |
1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
Average (%) | 94 | 98 | 108 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460