Product Name:
Human Nicotinic acetylcholine receptor (N-AChR) ELISA Kit
Cat.#:
JL46030
Regulatory Status:
Alternative:
nAChRs
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
78.12-5000pg/mL
Sensitivity:
38pg/mL
Specificity:
This kit recognizes Human N-AChR in samples. No significant cross-reactivity or interference between Human N-AChR and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:

Research Area:
Immunology
Product Datasheets
| N-AChR
Nicotinic acetylcholine receptors are receptor polypeptides that respond to the neurotransmitter acetylcholine.They're found in the central and peripheral nervous system, muscle, and many other tissues of many organisms. At the neuromuscular junction they're the primary receptor in muscle for motor nerve-muscle communication that controls muscle contraction. In the peripheral nervous system: they transmit outgoing signals from the presynaptic to the postsynaptic cells within the sympathetic and parasympathetic nervous system, and they're the receptors found on skeletal muscle that receive acetylcholine released to signal for muscular contraction.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (pg/mL) | 5000 | 2500 | 1250 | 625 | 312.5 | 156 | 78.12 | 0 |
OD | 2.36 | 1.78 | 1.23 | 0.79 | 0.46 | 0.29 | 0.17 | 0.09 |
Corrected OD | 2.27 | 1.69 | 1.14 | 0.7 | 0.37 | 0.2 | 0.08 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human N-AChR spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 83-102 | 97 |
Plasma(n=8) | 94-107 | 103 |
Cell Culture Supernates(n=8) | 96-108 | 107 |
| Linearity
Samples were spiked with high concentrations of Human N-AChR and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 83-96 | 88-96 | 90-110 |
Average (%) | 91 | 93 | 96 | |
1 : 4 | Range (%) | 89-103 | 88-108 | 105-115 |
Average (%) | 95 | 98 | 111 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460