Product Name:
Human p53-induced gene 3 protein (PIG3) ELISA Kit
Cat.#:
JL17317
Regulatory Status:
Alternative:
PIG3; Quinone oxidoreductase PIG3; p53-induced gene 3 protein;Tumor Protein p53 Inducible Protein 3
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
78-5000pg/mL
Sensitivity:
40pg/mL
Specificity:
This kit recognizes Human PIG3 in samples. No significant cross-reactivity or interference between Human PIG3 and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:

Research Area:
Immunology
Product Datasheets
| PIG3
Putative quinone oxidoreductase is an enzyme encoded by the TP53I3 gene.The protein encoded by this gene is similar to oxidoreductases, which are enzymes involved in cellular responses to oxidative stresses and irradiation. This gene is induced by the tumor suppressor p53 and is thought to be involved in p53-mediated cell death. It contains a p53 consensus binding site in its promoter region and a downstream pentanucleotide microsatellite sequence. P53 has been shown to transcriptionally activate this gene by interacting with the downstream pentanucleotide microsatellite sequence. The microsatellite is polymorphic, with a varying number of pentanucleotide repeats directly correlated with the extent of transcriptional activation by p53.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (pg/mL) | 5000 | 2500 | 1250 | 625 | 312 | 156 | 78 | 0 |
OD | 2.03 | 1.21 | 0.69 | 0.41 | 0.29 | 0.23 | 0.19 | 0.09 |
Corrected OD | 1.94 | 1.12 | 0.6 | 0.32 | 0.2 | 0.14 | 0.1 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human PIG3 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 85-101 | 96 |
Plasma(n=8) | 92-105 | 102 |
Cell Culture Supernates(n=8) | 96-108 | 104 |
| Linearity
Samples were spiked with high concentrations of Human PIG3 and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 84-95 | 86-96 | 90-110 |
Average (%) | 91 | 93 | 96 | |
1 : 4 | Range (%) | 88-103 | 87-108 | 105-115 |
Average (%) | 94 | 98 | 110 |






Size
Quantity
Price ($)
48T


360 / 360
96T