400-0066-400

Human Carboxypeptidase A3 (CPA3) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human Carboxypeptidase A3 (CPA3) ELISA Kit
Product Name:

Human Carboxypeptidase A3 (CPA3) ELISA Kit

Cat.#:

JL52542

Regulatory Status:
Alternative:

MC-CPA; Mast cell carboxypeptidase A; Carboxypeptidase A3, Mast Cell

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
7.8-500pg/mL
Sensitivity:
3.5pg/mL
Specificity:
This kit recognizes Human CPA3 in samples. No significant cross-reactivity or interference between Human CPA3 and analogues was observed.
Sample Type:
serum, plasma and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Immunology
  • Human Carboxypeptidase A3 (CPA3) ELISA Kit
  • Human Carboxypeptidase A3 (CPA3) ELISA Kit
  • Human Carboxypeptidase A3 (CPA3) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| CPA3

Carboxypeptidase A3 (mast cell carboxypeptidase A), also known as CPA3, is an enzyme encoded by the CPA3 gene. CPA3 shares significant homology with the CPA subfamily of metalloprecarboxypeptidases and all the residues essential for the coordination of the Zn2+ active site, substrate peptide anchoring, and CP activity are preserved in the putative CPA3 protein. It resembles pancreatic CPA1 in cleaving C-terminal aromatic and aliphatic amino acid residues. CPA3 contains an N-terminal sequence of 16 amino acids and a pro-peptide between the NH2-terminal signal peptide sequence and COOH-terminal CP moiety.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (pg/mL) 500 250 125 62.5 31.2 15.6 7.8 0
OD 2.26 1.49 1.03 0.7 0.46 0.32 0.23 0.08
Corrected OD 2.18 1.41 0.95 0.62 0.38 0.24 0.15 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human CPA3 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-106 103





 

| Linearity

Samples were spiked with high concentrations of Human CPA3 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4)
1 : 2 Range (%) 85-94 88-96
Average (%) 91 93
1 : 4 Range (%) 89-103 87-108
Average (%) 94 99







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
360 / 360
96T
1
460 / 460
Top