400-0066-400

Human Protein Disulfide Isomerase (PDI) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human Protein Disulfide Isomerase (PDI) ELISA Kit
Product Name:

Human Protein Disulfide Isomerase (PDI) ELISA Kit

Cat.#:

JL11812

Regulatory Status:
Alternative:

P4HB; ERBA2L; PDIA1; PO4DB; PROHB, DSI, GIT, PDI, PO4HB, P4Hbeta; Prolyl 4-Hydroxylase Subunit Beta; Procollagen-Proline 2-Oxoglutarate 4-Dioxygenase Beta Polypeptide

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.31-20ng/mL
Sensitivity:
0.12ng/mL
Specificity:
This kit recognizes Human PDI in samples. No significant cross-reactivity or interference between Human PDI and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Cancer
  • Human Protein Disulfide Isomerase (PDI) ELISA Kit
  • Human Protein Disulfide Isomerase (PDI) ELISA Kit
  • Human Protein Disulfide Isomerase (PDI) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| PDI

Protein disulfide isomerase (PDI) s an enzyme in the endoplasmic reticulum (ER) in eukaryotes and the periplasm of bacteria that catalyzes the formation and breakage of disulfide bonds between cysteine residues within proteins as they fold. This allows proteins to quickly find the correct arrangement of disulfide bonds in their fully folded state, and therefore the enzyme acts to catalyze protein folding. PDI displays oxidoreductase and isomerase properties, both of which depend on the type of substrate that binds to protein disulfide-isomerase and changes in protein disulfide-isomerase's redox state.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 20 10 5 2.5 1.25 0.62 0.31 0
OD 2.32 1.5 0.87 0.52 0.35 0.24 0.18 0.08
Corrected OD 2.24 1.42 0.79 0.44 0.27 0.16 0.1 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human PDI spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-105 102
Tissue Homogenates(n=8) 96-108 105





 

| Linearity

Samples were spiked with high concentrations of Human PDI and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Tissue Homogenates(n=4)
1 : 2 Range (%) 85-95 88-96 90-110
Average (%) 91 93 97
1 : 4 Range (%) 89-103 87-108 105-115
Average (%) 94 98 108







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
360 / 360
96T
1
460 / 460
Top