400-0066-400

Human Growth Arrest Specific Protein 6 (Gas6) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human Growth Arrest Specific Protein 6 (Gas6) ELISA Kit
Product Name:

Human Growth Arrest Specific Protein 6 (Gas6) ELISA Kit

Cat.#:

JL19793

Regulatory Status:
Alternative:

AXLLG; AXSF; AXL Stimulatory Factor; AXL receptor tyrosine kinase ligand

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.15-10ng/mL
Sensitivity:
0.06ng/mL
Specificity:
This kit recognizes Human Gas6in samples. No significant cross-reactivity or interference between Human Gas6 and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Immunology
  • Human Growth Arrest Specific Protein 6 (Gas6) ELISA Kit
  • Human Growth Arrest Specific Protein 6 (Gas6) ELISA Kit
  • Human Growth Arrest Specific Protein 6 (Gas6) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| Gas6

Growth arrest – specific 6, also known as GAS6, is a human gene coding for the GAS6 protein. It is similar to the Protein S with the same domain organization and 43% amino acid identity. It was originally found as a gene upregulated by growth arrested fibroblasts.Gas6 is a gamma-carboxyglutamic acid (Gla) domain-containing protein thought to be involved in the stimulation of cell proliferation.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 10 5 2.5 1.25 0.62 0.31 0.15 0
OD 2.36 1.36 0.8 0.48 0.34 0.28 0.23 0.09
Corrected OD 2.27 1.27 0.71 0.39 0.25 0.19 0.14 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human Gas6 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-102 96
Plasma(n=8) 92-106 103





 

| Linearity

Samples were spiked with high concentrations of Human Gas6 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4)
1 : 2 Range (%) 84-96 88-96
Average (%) 91 93
1 : 4 Range (%) 89-103 87-108
Average (%) 94 98







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
360 / 360
96T
1
460 / 460