400-0066-400

Human B-Lymphocyte Chemoattractant 1 (BLC-1;CXCL13) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human B-Lymphocyte Chemoattractant 1 (BLC-1;CXCL13) ELISA Kit
Product Name:

Human B-Lymphocyte Chemoattractant 1 (BLC-1;CXCL13) ELISA Kit

Cat.#:

JL10292

Regulatory Status:
Alternative:

CXCL13; SCYB13; BLC; BCA1; BLR1L; ANGIE; ANGIE2; Chemokine(C-X-C-Motif)ligand 13; Small Inducible Cytokine B Subfamily(Cys-X-Cys Motif)Member 13

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
15.62-1000pg/mL
Sensitivity:
5.83pg/mL
Specificity:
This kit recognizes Human BLC-1;CXCL13in samples. No significant cross-reactivity or interference between Human BLC-1;CXCL13 and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Immunology
  • Human B-Lymphocyte Chemoattractant 1 (BLC-1;CXCL13) ELISA Kit
  • Human B-Lymphocyte Chemoattractant 1 (BLC-1;CXCL13) ELISA Kit
  • Human B-Lymphocyte Chemoattractant 1 (BLC-1;CXCL13) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| BLC-1;CXCL13

Chemokine (C-X-C motif) ligand 13 (CXCL13), also known as B lymphocyte chemoattractant (BLC) or B cell-attracting chemokine 1 (BCA-1), is a protein ligand that in humans is encoded by the CXCL13 gene.CXCL13 is a small chemokine belonging to the CXC chemokine family. As its other names suggest, this chemokine is selectively chemotactic for B cells belonging to both the B-1 and B-2 subsets, and elicits its effects by interacting with chemokine receptor CXCR5.CXCL13 and its receptor CXCR5 control the organization of B cells within follicles of lymphoid tissues and is expressed highly in the liver, spleen, lymph nodes, and gut of humans.The gene for CXCL13 is located on human chromosome 4 in a cluster of other CXC chemokines.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (pg/mL) 1000 500 250 125 62.5 31.25 15.62 0
OD 2.24 1.63 1.01 0.55 0.44 0.31 0.25 0.09
Corrected OD 2.15 1.54 0.92 0.46 0.35 0.22 0.16 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human BLC-1;CXCL13 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 93-105 102
Cell Culture Supernates(n=8) 96-108 105





 

| Linearity

Samples were spiked with high concentrations of Human BLC-1;CXCL13 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Cell Culture Supernates(n=4)
1 : 2 Range (%) 84-95 87-96 90-110
Average (%) 91 93 96
1 : 4 Range (%) 88-103 87-108 105-116
Average (%) 94 98 108







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
360 / 360
96T
1
460 / 460