Product Name:
Human Cluster Of Differentiation 160 (CD160) ELISA Kit
Cat.#:
JL15048
Regulatory Status:
Alternative:
BY55; NK1; NK28; CD160 Antigen; Natural killer cell receptor BY55
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
78.12-5000pg/mL
Sensitivity:
29.35pg/mL
Specificity:
This kit recognizes Human CD160 in samples. No significant cross-reactivity or interference between Human CD160 and analogues was observed.
Sample Type:
serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:

Research Area:
Cell Biology
Product Datasheets
| CD160
CD16 is a 27 kDa glycoprotein, and its expression is tightly associated with peripheral blood NK cells and CD8 T lymphocytes with cytolytic effector activity.RNA blot analysis revealed CD16 mRNAs of 1.5 and 1.6 kb whose expression was highly restricted to circulating NK and T cells, spleen and small intestine. In tissues, CD16 is expressed on all intestinal intraepithelial lymphocytesCD16 is a ligand for HVEM, and considered a proposed immune checkpoint inhibitor with anti-cancer activity along with anti- PD-1 antibodies.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (pg/mL) | 5000 | 2500 | 1250 | 625 | 312.5 | 156.25 | 78.12 | 0 |
OD | 2.51 | 1.96 | 1.24 | 0.72 | 0.46 | 0.3 | 0.22 | 0.09 |
Corrected OD | 2.42 | 1.87 | 1.15 | 0.63 | 0.37 | 0.21 | 0.13 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human CD160 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 84-101 | 96 |
Plasma(n=8) | 92-105 | 102 |
Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human CD160 and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
Average (%) | 91 | 93 | 95 | |
1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
Average (%) | 94 | 98 | 108 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460