400-0066-400

Human Extracellular Matrix Metalloproteinase Inducer (CD147) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human Extracellular Matrix Metalloproteinase Inducer (CD147) ELISA Kit
Product Name:

Human Extracellular Matrix Metalloproteinase Inducer (CD147) ELISA Kit

Cat.#:

JL14293

Regulatory Status:
Alternative:

EMMPRIN; BSG; 5F7; M6; OK; TCSF; Basigin(Ok Blood Group); Collagenase stimulatory factor; OK blood group antigen; Tumor cell-derived collagenase stimulatory factor

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
31.25-2000pg/mL
Sensitivity:
11.45pg/mL
Specificity:
This kit recognizes Human CD147 in samples. No significant cross-reactivity or interference between Human CD147 and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Cell Biology
  • Human Extracellular Matrix Metalloproteinase Inducer (CD147) ELISA Kit
  • Human Extracellular Matrix Metalloproteinase Inducer (CD147) ELISA Kit
  • Human Extracellular Matrix Metalloproteinase Inducer (CD147) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| CD147

Extracellular Matrix Metalloproteinase Inducer (EMMPRIN) also known as Basigin (BSG), is a protein encoded by the BSG gene. This protein is a determinant for the Ok blood group system. There are three known antigens in the Ok system; the most common being Oka (also called OK1), OK2 and OK3.Basigin is a member of the immunoglobulin superfamily, with a structure related to the putative primordial form of the family. As members of the immunoglobulin superfamily play fundamental roles in intercellular recognition involved in various immunologic phenomena, differentiation, and development, basigin is thought also to play a role in intercellular recognition
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (pg/mL) 2000 1000 500 250 125 62.5 31.25 0
OD 2.48 1.45 0.93 0.54 0.36 0.24 0.16 0.06
Corrected OD 2.42 1.39 0.87 0.48 0.3 0.18 0.1 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human CD147 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-105 102
Tissue Homogenates(n=8) 96-108 105





 

| Linearity

Samples were spiked with high concentrations of Human CD147 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Tissue Homogenates(n=4)
1 : 2 Range (%) 84-95 88-96 90-110
Average (%) 91 93 96
1 : 4 Range (%) 89-103 87-108 104-115
Average (%) 94 98 108







 