Product Name:
Human Urotensin 2 (UST2) ELISA Kit
Cat.#:
JL19870
Regulatory Status:
Alternative:
UII; U-II; UCN2; PRO1068; Urotensin-II
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
15.62-1000pg/mL
Sensitivity:
6.62pg/mL
Specificity:
This kit recognizes Human UST2 in samples. No significant cross-reactivity or interference between Human UST2 and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:

Research Area:
Neuroscience
Product Datasheets
| UST2
Urotensin-2 (UST2 or U-II) is a peptide ligand that is the strongest known vasoconstrictor. Because of the involvement of the UII system in multiple biological systems such as the cardiovascular, nervous, endocrine, and renal. U-II was initially isolated from the neurosecretory system of the Goby fish (Gillichthys mirabilis). U-II is an agonist for the urotensin-II receptor which is a G protein-coupled receptor that primarily activates the alpha subunit Gαq11. U-II has been linked to cardiac fibrosis and hypertrophy, heart failure, renal dysfunction, and diabetes.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (pg/mL) | 1000 | 500 | 250 | 125 | 62.5 | 31.25 | 15.62 | 0 |
OD | 2.39 | 1.48 | 0.86 | 0.51 | 0.32 | 0.23 | 0.18 | 0.07 |
Corrected OD | 2.32 | 1.41 | 0.79 | 0.44 | 0.25 | 0.16 | 0.11 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human UST2 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 82-101 | 94 |
Plasma(n=8) | 93-105 | 102 |
Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human UST2 and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
Average (%) | 91 | 93 | 96 | |
1 : 4 | Range (%) | 87-103 | 87-108 | 105-115 |
Average (%) | 92 | 98 | 108 |






Size
Quantity
Price ($)
48T


360 / 360
96T


460 / 460