400-0066-400

Human A Disintegrin And Metalloprotease 17 (ADAM17) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human A Disintegrin And Metalloprotease 17 (ADAM17) ELISA Kit
Product Name:

Human A Disintegrin And Metalloprotease 17 (ADAM17) ELISA Kit

Cat.#:

JL20069

Regulatory Status:
Alternative:

CD156b; TACE; CSVP; Tumor Necrosis Factor,Alpha,Converting Enzyme; Disintegrin and metalloproteinase domain-containing protein 17; Snake venom-like protease

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.15-10ng/mL
Sensitivity:
0.05ng/mL
Specificity:
This kit recognizes Human ADAM17 in samples. No significant cross-reactivity or interference between Human ADAM17 and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Neuroscience
  • Human A Disintegrin And Metalloprotease 17 (ADAM17) ELISA Kit
  • Human A Disintegrin And Metalloprotease 17 (ADAM17) ELISA Kit
  • Human A Disintegrin And Metalloprotease 17 (ADAM17) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| ADAM17

A disintegrin and metalloprotease 17 (ADAM17), also called TACE (tumor necrosis factor-α-converting enzyme), is a 7-kDa enzyme that belongs to the ADAM protein family of disintegrins and metalloproteases, activated by substrate presentation. ADAM17 is understood to be involved in the processing of tumor necrosis factor alpha (TNF-α) at the surface of the cell, and from within the intracellular membranes of the trans-Golgi network. This process, which is also known as 'shedding', involves the cleavage and release of a soluble ectodomain from membrane-bound pro-proteins (such as pro-TNF-α), and is of known physiological importance.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 10 5 2.5 1.25 0.625 0.312 0.15 0
OD 2.36 1.36 0.8 0.48 0.34 0.26 0.22 0.09
Corrected OD 2.27 1.27 0.71 0.39 0.25 0.17 0.13 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human ADAM17 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-104 101
Cell Culture Supernates(n=8) 97-108 105





 

| Linearity

Samples were spiked with high concentrations of Human ADAM17 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Cell Culture Supernates(n=4)
1 : 2 Range (%) 84-96 88-96 90-110
Average (%) 92 93 96
1 : 4 Range (%) 89-103 87-108 105-115
Average (%) 94 98 108







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
360 / 360
96T
1
460 / 460