400-0066-400

Mouse Interleukin 2 (IL-2) ELISA Kit

Home  >  Microsample ELISA Kits  >  Mouse Interleukin 2 (IL-2) ELISA Kit
Product Name:

Mouse Interleukin 2 (IL-2) ELISA Kit

Cat.#:

JLW20256

Regulatory Status:
Alternative:

IL1RN; IL1-RA; ICIL1RA; IL1ra3; IL1F3; IRAP;IL-1RA; Interleukin-1 Family Member 3; IL1 inhibitor; Anakinra

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
1.56-100pg/mL
Sensitivity:
0.72pg/mL
Specificity:
This kit recognizes Mouse IL-2 in samples. No significant cross-reactivity or interference between Mouse IL-2 and analogues was observed.
Sample Type:
Other biological fluids, plasma, serum
Assay Procedure:
Assay Procedure
Research Area:
Immunology
  • Mouse Interleukin 2 (IL-2) ELISA Kit
  • Mouse Interleukin 2 (IL-2) ELISA Kit
  • Mouse Interleukin 2 (IL-2) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| IL-2

Interleukin-2 (IL-2) is an interleukin, which is a type of cytokine signaling molecule forming part of the immune system. It is a 15.5–16 kDa protein that regulates the activities of white blood cells (leukocytes, often lymphocytes) that are responsible for immunity. IL-2 is part of the body's natural response to microbial infection, and in discriminating between foreign ("non-self") and "self". IL-2 mediates its effects by binding to IL-2 receptors, which are expressed by lymphocytes. The major sources of IL-2 are activated CD4+ T cells and activated CD8+ T cells. Put shortly the function of IL-2 is to stimulate the growth of helper, cytotoxic and regulatory T cells.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (pg/mL) 100 50 25 12.5 6.25 3.12 1.56 0
OD 2.48 1.65 1.07 0.71 0.45 0.28 0.19 0.09
Corrected OD 2.39 1.56 0.98 0.62 0.36 0.19 0.1 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Mouse IL-2 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 91-105 102





 

| Linearity

Samples were spiked with high concentrations of Mouse IL-2 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4)
1 : 2 Range (%) 84-95 88-97
Average (%) 91 92
1 : 4 Range (%) 89-105 86-108
Average (%) 94 97







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
220 / 220
96T
1
360 / 360