Product Name:
Trastuzumab (Trastuzumab) ELISA Kit
Cat.#:
JL21360
Regulatory Status:
Alternative:
Trastuzumab
Detection Method:
ELISA
Assay Type:
Indirect
Detection Range:
1.56-100ng/mL
Sensitivity:
0.78ng/mL
Specificity:
This kit recognizes Human Trastuzumab in samples. No significant cross-reactivity or interference between Human Trastuzumab and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Research Area:
Pesticide Residues & Drug Metabolism
Product Datasheets
| Trastuzumab
Trastuzumab, sold under the brand name Herceptin among others, is a monoclonal antibody used to treat breast cancer and stomach cancer.It is specifically used for cancer that is HER2 receptor positive.It may be used by itself or together with other chemotherapy medication.Trastuzumab is given by slow injection into a vein and injection just under the skin.Common side effects include fever, infection, cough, headache, trouble sleeping, and rash.Other severe side effects include heart failure, allergic reactions, and lung disease.Use during pregnancy may harm the baby.Trastuzumab works by binding to the HER2 receptor and slowing down cell replication.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 100 | 50 | 25 | 12.5 | 6.25 | 3.12 | 1.56 | 0 |
| OD | 2.52 | 1.96 | 1.38 | 0.97 | 0.55 | 0.31 | 0.19 | 0.08 |
| Corrected OD | 2.44 | 1.88 | 1.3 | 0.89 | 0.47 | 0.23 | 0.11 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human Trastuzumab spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 84-101 | 96 |
| Plasma(n=8) | 92-105 | 102 |
| Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human Trastuzumab and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
| Average (%) | 91 | 93 | 96 | |
| 1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
| Average (%) | 94 | 98 | 108 |
Size
Quantity
Price ($)
48T
1
460 / 460
96T
1
760 / 760