400-0066-400

Human Gevokizumab (Gevokizumab) ELISA Kit

Home  >  Indirect ELSA Kits  >  Human Gevokizumab (Gevokizumab) ELISA Kit
Product Name:

Human Gevokizumab (Gevokizumab) ELISA Kit

Cat.#:

JL58334

Regulatory Status:
Alternative:

Gevokizumab

Detection Method:
ELISA
Assay Type:
Indirect
Detection Range:
0.78-50ng/mL
Sensitivity:
0.52ng/mL
Specificity:
This kit recognizes Human Gevokizumab in samples. No significant cross-reactivity or interference between Human Gevokizumab and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Immunology
  • Human Gevokizumab (Gevokizumab) ELISA Kit
  • Human Gevokizumab (Gevokizumab) ELISA Kit
  • Human Gevokizumab (Gevokizumab) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| Gevokizumab

Gevokizumab is an experimental monoclonal antibody with allosteric modulating properties. It binds to interleukin-1 beta (IL-1β), a pro-inflammatory cytokine, and down-modulates the cellular signaling events that produce inflammation. IL-1β has been implicated in various diseases such as cardiovascular conditions, lung cancer, and auto-inflammatory diseases. Gevokizumab has been used in trials studying the treatment of acne vulgaris, osteoarthritis, Behcet's uveitis, pyoderma gangrenosum, and other diseases.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 50 25 12.5 6.25 3.12 1.56 0.78 0
OD 2.72 1.63 0.9 0.54 0.35 0.27 0.22 0.08
Corrected OD 2.64 1.55 0.82 0.46 0.27 0.19 0.14 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of HumanGevokizumab spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-105 102
Cell Culture Supernates(n=8) 96-108 102





 

| Linearity

Samples were spiked with high concentrations of HumanGevokizumab and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Cell Culture Supernates(n=4)
1 : 2 Range (%) 84-98 88-96 90-110
Average (%) 91 93 96
1 : 4 Range (%) 89-103 87-108 105-115
Average (%) 94 98 108







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
460 / 460
96T
1
760 / 760
Top