Product Name:
Human Gevokizumab (Gevokizumab) ELISA Kit
Cat.#:
JL58334
Regulatory Status:
Alternative:
Gevokizumab
Detection Method:
ELISA
Assay Type:
Indirect
Detection Range:
0.78-50ng/mL
Sensitivity:
0.52ng/mL
Specificity:
This kit recognizes Human Gevokizumab in samples. No significant cross-reactivity or interference between Human Gevokizumab and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:

Research Area:
Immunology
Product Datasheets
| Gevokizumab
Gevokizumab is an experimental monoclonal antibody with allosteric modulating properties. It binds to interleukin-1 beta (IL-1β), a pro-inflammatory cytokine, and down-modulates the cellular signaling events that produce inflammation. IL-1β has been implicated in various diseases such as cardiovascular conditions, lung cancer, and auto-inflammatory diseases. Gevokizumab has been used in trials studying the treatment of acne vulgaris, osteoarthritis, Behcet's uveitis, pyoderma gangrenosum, and other diseases.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (ng/mL) | 50 | 25 | 12.5 | 6.25 | 3.12 | 1.56 | 0.78 | 0 |
OD | 2.72 | 1.63 | 0.9 | 0.54 | 0.35 | 0.27 | 0.22 | 0.08 |
Corrected OD | 2.64 | 1.55 | 0.82 | 0.46 | 0.27 | 0.19 | 0.14 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of HumanGevokizumab spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 84-101 | 96 |
Plasma(n=8) | 92-105 | 102 |
Cell Culture Supernates(n=8) | 96-108 | 102 |
| Linearity
Samples were spiked with high concentrations of HumanGevokizumab and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 84-98 | 88-96 | 90-110 |
Average (%) | 91 | 93 | 96 | |
1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
Average (%) | 94 | 98 | 108 |