Product Name:
Human Elotuzumab (Elotuzumab) ELISA Kit
Cat.#:
JL58360
Regulatory Status:
Alternative:
Elotuzumab
Detection Method:
ELISA
Assay Type:
Indirect
Detection Range:
0.78-50ng/mL
Sensitivity:
0.54ng/mL
Specificity:
This kit recognizes Human Elotuzumab in samples. No significant cross-reactivity or interference between Human Elotuzumab and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:

Research Area:
Cancer
Product Datasheets
| Elotuzumab
Elotuzumab is an immunostimulatory antibody that targets signaling lymphocyte activation molecule family member 7, also known as SLAMF7.SLAMF7 is a cell surface glycoprotein that is present on myeloma cells, natural killer cells, plasma cells, and subsets of immune cells of the hematopoietic lineage. Elotuzumab works by activating the natural killer cells through the SLAMF7 pathway.Along with that, the SLAMF7 of the myeloma cells are targeted and flagged, for natural killer cell-mediated destruction through antibody-dependent cellular toxicity.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (ng/mL) | 50 | 25 | 12.5 | 6.25 | 3.12 | 1.56 | 0.78 | 0 |
OD | 2.69 | 1.89 | 1.32 | 0.8 | 0.47 | 0.31 | 0.16 | 0.1 |
Corrected OD | 2.59 | 1.79 | 1.22 | 0.7 | 0.37 | 0.21 | 0.06 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of HumanElotuzumab spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 84-101 | 96 |
Plasma(n=8) | 92-105 | 102 |
Cell Culture Supernates(n=8) | 96-108 | 102 |
| Linearity
Samples were spiked with high concentrations of HumanElotuzumab and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 84-98 | 88-99 | 90-110 |
Average (%) | 91 | 93 | 96 | |
1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
Average (%) | 94 | 98 | 108 |






Size
Quantity
Price ($)
48T


396 / 396
96T


576 / 576