Product Name:
Human Lecanemab (Lecanemab) ELISA Kit
Cat.#:
JL58285
Regulatory Status:
Alternative:
Lecanemab
Detection Method:
ELISA
Assay Type:
Indirect
Detection Range:
0.78-50ng/mL
Sensitivity:
0.46ng/mL
Specificity:
This kit recognizes Human Lecanemab in samples. No significant cross-reactivity or interference between Human Lecanemab and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Procedure:

Research Area:
Neuroscience
Product Datasheets
| Lecanemab
Lecanemab is a monoclonal antibody medication used for the treatment of Alzheimer's disease.Lecanemab is an amyloid beta-directed antibody.It is given via intravenous infusion to patients with mild cognitive impairment or mild dementia.In clinical trials, it demonstrated modest efficacy in reducing relative cognitive decline compared to placebo.The most common side effects of lecanemab include headache, infusion-related reactions, and amyloid-related imaging abnormalities, a side effect known to occur with the class of antibodies targeting amyloid.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.Concentration (ng/mL) | 50 | 25 | 12.5 | 6.25 | 3.12 | 1.56 | 0.78 | 0 |
OD | 2.42 | 1.55 | 0.88 | 0.49 | 0.29 | 0.19 | 0.14 | 0.07 |
Corrected OD | 2.35 | 1.48 | 0.81 | 0.42 | 0.22 | 0.12 | 0.07 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of HumanLecanemab spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.Sample Type | Range(%) | Average Recovery(%) |
Serum(n=8) | 84-108 | 90 |
Plasma(n=8) | 90-106 | 97 |
Cell Culture Supernates(n=8) | 95-111 | 99 |
| Linearity
Samples were spiked with high concentrations of HumanLecanemab and diluted with Universal Diluent to produce samples with values within the range of the assay.Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
1 : 2 | Range (%) | 84-98 | 88-96 | 90-110 |
Average (%) | 92 | 90 | 95 | |
1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
Average (%) | 96 | 93 | 105 |






Size
Quantity
Price ($)
48T


560 / 560
96T


840 / 840