400-0066-400

Rat 8-Hydroxydeoxyguanosine (8-OHdG) ELISA Kit

Home  >  Competitive ELISA Kits  >  Rat 8-Hydroxydeoxyguanosine (8-OHdG) ELISA Kit
Product Name:

Rat 8-Hydroxydeoxyguanosine (8-OHdG) ELISA Kit

Cat.#:

JL12002

Regulatory Status:
Alternative:

8OHdG; 7;8-Dihydro-8-Oxo-2'-Deoxyguanosine; 7;8-Dihydro-8-Oxodeoxyguanosine; 8-Hydroxy-2'-Deoxyguanosine; 8-Oxo-DG

Detection Method:
ELISA
Assay Type:
Competitive
Detection Range:
93.75-6000pg/mL
Sensitivity:
46.6pg/mL
Specificity:
This kit recognizes Rat 8-OHdG in samples. No significant cross-reactivity or interference between Rat 8-OHdG and analogues was observed.
Sample Type:
Serum;plasma and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Metabolism
  • Rat 8-Hydroxydeoxyguanosine (8-OHdG) ELISA Kit
  • Rat 8-Hydroxydeoxyguanosine (8-OHdG) ELISA Kit
  • Rat 8-Hydroxydeoxyguanosine (8-OHdG) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| 8-OHdG

8-Oxo-2'-deoxyguanosine (8-oxo-dG) is an oxidized derivative of deoxyguanosine. 8-Oxo-dG is one of the major products of DNA oxidation.Concentrations of 8-oxo-dG within a cell are a measurement of oxidative stress.8-oxo-dG increases with age in DNA of mammalian tissues.8-oxo-dG increases in both mitochondrial DNA and nuclear DNA with age.When 8-oxo-dG is induced by a DNA damaging agent it is rapidly repaired. For example, 8-oxo-dG was increased 10-fold in the livers of mice subjected to ionizing radiation, but the excess 8-oxo-dG was rapidly removed with a half-life of 11 minutes.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (pg/mL) 6000 3000 1500 750 375 187.5 93.75 0
OD 0.216 0.298 0.417 0.669 0.955 1.405 1.79 1.865
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Rat 8-OHdG spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 81-101 96
Plasma(n=8) 92-105 101





 

| Linearity

Samples were spiked with high concentrations of Rat 8-OHdG and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4)
1 : 2 Range (%) 83-95 88-96
Average (%) 91 93
1 : 4 Range (%) 89-104 87-108
Average (%) 93 98







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
360 / 360
96T
1
460 / 460