Product Name:
Rat Malondialdehyde (MDA) ELISA Kit
Cat.#:
JL13297
Regulatory Status:
Alternative:
MDA;Malonic aldehyde;Malonodialdehyde;Propanedial;1,3-Propanedial;Malonaldehyde;Malonyldialdehyde;propanedial
Detection Method:
ELISA
Assay Type:
Competitive
Detection Range:
0.312-20ng/mL
Sensitivity:
0.151ng/mL
Specificity:
This kit recognizes Rat MDA in samples. No significant cross-reactivity or interference between Rat MDA and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Research Area:
Signal Transduction
Product Datasheets
| MDA
Malondialdehyde belong to the class of β-dicarbonyls. A colorless liquid, malondialdehyde is a highly reactive compound that occurs as the enol.It is a physiological metabolite, and a marker for oxidative stress.Malondialdehyde results from lipid peroxidation of polyunsaturated fatty acids.It is a prominent product in thromboxane A2 synthesis wherein cyclooxygenase 1 or cycloxygenase 2 metabolizes arachidonic acid to prostaglandin H2 by platelets and a wide array of other cell types and tissues.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 20 | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0 |
| OD | 0.216 | 0.298 | 0.417 | 0.669 | 0.955 | 1.405 | 1.79 | 1.865 |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Rat MDA spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 81-101 | 96 |
| Plasma(n=8) | 92-105 | 102 |
| Cell Culture Supernates(n=8) | 97-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Rat MDA and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 83-95 | 88-96 | 90-110 |
| Average (%) | 91 | 93 | 96 | |
| 1 : 4 | Range (%) | 89-104 | 87-107 | 105-115 |
| Average (%) | 93 | 97 | 110 |
Size
Quantity
Price ($)
48T
1
396 / 396
96T
1
516 / 516