Product Name:
Rat Urinary 17-ketosteroids (17-ketosteroide) ELISA Kit
Cat.#:
JL10462
Regulatory Status:
Alternative:
Urinary 17-ketosteroids
Detection Method:
ELISA
Assay Type:
Competitive
Detection Range:
62.5-4000pg/mL
Sensitivity:
31.9pg/mL
Specificity:
This kit recognizes Rat 17-ketosteroide in samples. No significant cross-reactivity or interference between Rat 17-ketosteroide and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Research Area:
Metabolism
Product Datasheets
| 17-ketosteroide
17β-Hydroxysteroid dehydrogenases (17β-HSD, HSD17B), also 17-ketosteroid reductases (17-KSR), are a group of alcohol oxidoreductases which catalyze the reduction of 17-ketosteroids and the dehydrogenation of 17β-hydroxysteroids in steroidogenesis and steroid metabolism.This includes interconversion of DHEA and androstenediol, androstenedione and testosterone, and estrone and estradiol.The major reactions catalyzed by 17β-HSD (e.g., the conversion of androstenedione to testosterone) are in fact hydrogenation (reduction) rather than dehydrogenation (oxidation) reactions.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (pg/mL) | 4000 | 2000 | 1000 | 500 | 250 | 125 | 62.5 | 0 |
| OD | 0.19 | 0.24 | 0.31 | 0.55 | 0.97 | 1.38 | 1.96 | 2.52 |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Rat 17-ketosteroide spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 81-101 | 96 |
| Plasma(n=8) | 92-105 | 101 |
| Cell Culture Supernates(n=8) | 97-107 | 104 |
| Linearity
Samples were spiked with high concentrations of Rat 17-ketosteroide and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 83-95 | 88-96 | 90-110 |
| Average (%) | 91 | 93 | 96 | |
| 1 : 4 | Range (%) | 89-105 | 87-108 | 105-115 |
| Average (%) | 94 | 98 | 110 |
Size
Quantity
Price ($)
48T
1
360 / 360
96T
1
460 / 460