Product Name:
Pig Lactate Dehydrogenase A (LDHA) ELISA Kit
Cat.#:
JL55451
Regulatory Status:
Alternative:
LDH-A; LDH-M; LDH1; PIG19; Cell proliferation-inducing gene 19 protein; LDH muscle subunit; Renal carcinoma antigen NY-REN-59
Detection Method:
ELISA
Assay Type:
Competitive
Detection Range:
3.12-200U/L
Sensitivity:
1.16U/L
Specificity:
This kit recognizes Pig LDHA in samples. No significant cross-reactivity or interference between Pig LDHA and analogues was observed.
Sample Type:
Serum, plasma, tissue homogenate and other biological fluids
Assay Procedure:
Research Area:
Metabolism
Product Datasheets
| LDHA
Lactate dehydrogenase A (LDHA) is an enzyme encoded by the LDHA gene. It is a monomer of lactate dehydrogenase B, existing as a tetramer. The other major subunit is lactate dehydrogenase B (LDHB). LDHA catalyzes the interconversion of pyruvate and L-lactic acid, while simultaneously catalyzing the interconversion of NADH and NAD+. It is present in most somatic tissues, though predominantly found in muscle tissue and tumors, and belongs to the lactate dehydrogenase family. LDHA levels are elevated in many cancers compared to normal tissues.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (U/L) | 200 | 100 | 50 | 25 | 12.5 | 6.25 | 3.12 | 0 |
| OD | 0.17 | 0.3 | 0.48 | 0.72 | 1.05 | 1.42 | 1.91 | 2.26 |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Pig LDHA spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 85-103 | 97 |
| Plasma(n=8) | 91-109 | 101 |
| Cell Culture Supernates(n=8) | 97-111 | 105 |
| Linearity
Samples were spiked with high concentrations of Pig LDHA and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 82-95 | 82-96 | 92-110 |
| Average (%) | 92 | 91 | 98 | |
| 1 : 4 | Range (%) | 89-102 | 87-110 | 104-115 |
| Average (%) | 92 | 97 | 109 |
Size
Quantity
Price ($)
48T
1
320 / 320
96T
1
576 / 576