Product Name:
Pig Angiotensin Ⅱ (Ang-Ⅱ) ELISA Kit
Cat.#:
JL11927
Regulatory Status:
Alternative:
Ang-II; Angiotensin-2
Detection Method:
ELISA
Assay Type:
Competitive
Detection Range:
0.78-50pg/mL
Sensitivity:
0.34pg/mL
Specificity:
This kit recognizes Pig Ang-Ⅱ in samples. No significant cross-reactivity or interference between Pig Ang-Ⅱ and analogues was observed.
Sample Type:
Serum; plasma; tissue homogenates; cell lysates; cell culture supernates and other biological fluids
Assay Procedure:
Research Area:
Cardiovascular Biology
Product Datasheets
| Ang-Ⅱ
Angiotensin is a peptide hormone that causes vasoconstriction and an increase in blood pressure. It is part of the renin–angiotensin system, which regulates blood pressure. Angiotensinogen is also known as renin substrate. It is cleaved at the N-terminus by renin to result in angiotensin I, which will later be modified to become angiotensin II.Angiotensin II acts on the central nervous system to increase vasopressin production, and also acts on venous and arterial smooth muscle to cause vasoconstriction. Angiotensin II also increases aldosterone secretion; it therefore acts as an endocrine, autocrine/paracrine, and intracrine hormone.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (pg/mL) | 50 | 25 | 12.5 | 6.25 | 3.12 | 1.56 | 0.78 | 0 |
| OD | 0.216 | 0.298 | 0.417 | 0.669 | 0.955 | 1.405 | 1.79 | 1.865 |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Pig Ang-Ⅱ spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 81-101 | 96 |
| Plasma(n=8) | 92-105 | 101 |
| Cell Culture Supernates(n=8) | 97-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Pig Ang-Ⅱ and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 83-95 | 88-96 | 90-110 |
| Average (%) | 91 | 93 | 96 | |
| 1 : 4 | Range (%) | 89-104 | 87-108 | 105-115 |
| Average (%) | 93 | 98 | 110 |
Size
Quantity
Price ($)
48T
1
360 / 360
96T
1
460 / 460