400-0066-400

Mouse Luteinizing Hormone (LH) ELISA Kit

Home  >  Competitive ELISA Kits  >  Mouse Luteinizing Hormone (LH) ELISA Kit
Product Name:

Mouse Luteinizing Hormone (LH) ELISA Kit

Cat.#:

JL10432

Regulatory Status:
Alternative:

ICSH; Lutropin; Interstitial Cell Stimulating Hormone

Detection Method:
ELISA
Assay Type:
Competitive
Detection Range:
1.56-100mIU/mL
Sensitivity:
0.75mIU/mL
Specificity:
This kit recognizes Mouse LH in samples. No significant cross-reactivity or interference between Mouse LH and analogues was observed.
Sample Type:
Serum;plasma and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Neuroscience
  • Mouse Luteinizing Hormone (LH) ELISA Kit
  • Mouse Luteinizing Hormone (LH) ELISA Kit
  • Mouse Luteinizing Hormone (LH) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| LH

Luteinizing hormone (LH) is a hormone produced by gonadotropic cells in the anterior pituitary gland. The production of LH is regulated by gonadotropin-releasing hormone (GnRH) from the hypothalamus. LH is a heterodimeric glycoprotein, a functional protein consisting of one subunit and one subunit. Its structure is similar to that of other glycoprotein hormones, follicle-stimulating hormone (FSH), thyrotropin (TSH) and human chorionic gonadotropin (hCG).The protein dimer contains 2 glycopeptidic subunits (labeled alpha- and beta- subunits) that are non-covalently associated.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (mIU/mL) 100 50 25 12.5 6.25 3.12 1.56 0
OD 0.216 0.298 0.417 0.669 0.955 1.405 1.79 1.865
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Mouse LH spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-105 102





 

| Linearity

Samples were spiked with high concentrations of Mouse LH and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4)
1 : 2 Range (%) 85-95 88-96
Average (%) 91 93
1 : 4 Range (%) 89-103 87-108
Average (%) 94 98







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
360 / 360
96T
1
460 / 460
Top