Product Name:
Mouse Lipase, Pancreatic (PL) ELISA Kit
Cat.#:
JL20656
Regulatory Status:
Alternative:
PNLIP; PTL; Pancreatic Lipase; Pancreatic triacylglycerol lipase
Detection Method:
ELISA
Assay Type:
Competitive
Detection Range:
1.56-100ng/mL
Sensitivity:
0.72ng/mL
Specificity:
This kit recognizes Mouse PL in samples. No significant cross-reactivity or interference between Mouse PL and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates and other biological fluids
Assay Procedure:
Research Area:
Metabolism
Product Datasheets
| PL
Pancreatic lipase, also known as pancreatic triacylglycerol lipase or steapsin, is an enzyme secreted from the pancreas. As the primary lipase enzyme that hydrolyzes (breaks down) dietary fat molecules in the human digestive system, it is one of the main digestive enzymes, converting triglyceride substrates like 1 found in ingested oils to monoglycerides 3 and free fatty acids 2a and 2b.Bile salts secreted from the liver and stored in gallbladder are released into the duodenum, where they coat and emulsify large fat droplets into smaller droplets, thus increasing the overall surface area of the fat, which allows the lipase to break apart the fat more effectively.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 100 | 50 | 25 | 12.5 | 6.25 | 3.12 | 1.56 | 0 |
| OD | 0.19 | 0.27 | 0.48 | 0.89 | 1.47 | 2.02 | 2.3 | 2.66 |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Mouse PL spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 84-101 | 96 |
| Plasma(n=8) | 92-106 | 103 |
| Tissue Homogenates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Mouse PL and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Tissue Homogenates(n=4) | ||
| 1 : 2 | Range (%) | 82-93 | 88-96 | 91-110 |
| Average (%) | 90 | 91 | 97 | |
| 1 : 4 | Range (%) | 88-103 | 87-110 | 105-115 |
| Average (%) | 92 | 95 | 109 |
Size
Quantity
Price ($)
48T
1
360 / 360
96T
1
460 / 460