400-0066-400

Mouse Androstrone (Androstrone) ELISA Kit

Home  >  Competitive ELISA Kits  >  Mouse Androstrone (Androstrone) ELISA Kit
Product Name:

Mouse Androstrone (Androstrone) ELISA Kit

Cat.#:

JL52707

Regulatory Status:
Alternative:

3α-hydroxy-5α-androstan-17-one; 5α-androstan-3α-ol-17-one

Detection Method:
ELISA
Assay Type:
Competitive
Detection Range:
62.5-4000pg/mL
Sensitivity:
31.4pg/mL
Specificity:
This kit recognizes Mouse Androstrone in samples. No significant cross-reactivity or interference between Mouse Androstrone and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Metabolism
  • Mouse Androstrone (Androstrone) ELISA Kit
  • Mouse Androstrone (Androstrone) ELISA Kit
  • Mouse Androstrone (Androstrone) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| Androstrone

Androstenone (5α-androst-16-en-3-one) is a 16-androstene class steroidal pheromone.Androstenone is synthesized from androstadienone by 5α-reductase, and can be converted into 3α-androstenol or 3β-androstenol by 3-ketosteroid reductase.Androstenone was the first mammalian pheromone to be identified.Depending upon the subject, androstenone can have an unpleasant, sweaty, urinous smell, a woody smell, or even a pleasant floral smell.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (pg/mL) 4000 2000 1000 500 250 125 62.5 0
OD 0.19 0.24 0.31 0.55 0.97 1.38 1.96 2.52
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Mouse Androstrone spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 81-101 96
Plasma(n=8) 92-105 101





 

| Linearity

Samples were spiked with high concentrations of Mouse Androstrone and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4)
1 : 2 Range (%) 83-95 88-96
Average (%) 91 93
1 : 4 Range (%) 89-104 87-108
Average (%) 93 98







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
360 / 360
96T
1
460 / 460
Top