Product Name:
Mouse Folic Acid (Folic Acid) ELISA Kit
Cat.#:
JL20648
Regulatory Status:
Alternative:
VB9; Vitamin B9; Folacin; Folate; V; Itamin M; Vitamin M; Vitamin Bc; Pteroyl-L-Glutamic Acid; Pteroyl-L-Glutamate;folic acid
Detection Method:
ELISA
Assay Type:
Competitive
Detection Range:
1.56-100ng/mL
Sensitivity:
0.68ng/mL
Specificity:
This kit recognizes Mouse Folic Acid in samples. No significant cross-reactivity or interference between Mouse Folic Acid and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Research Area:
Metabolism
Product Datasheets
| Folic Acid
Folic acid(Folate), also known as vitamin B9 and folacin,is one of the B vitamins.Manufactured folic acid, which is converted into folate by the body, is used as a dietary supplement and in food fortification as it is more stable during processing and storage.Folate is required for the body to make DNA and RNA and metabolise amino acids necessary for cell division and maturation of blood cells.As the human body cannot make folate, it is required in the diet, making it an essential nutrient.It occurs naturally in many foods.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 100 | 50 | 25 | 12.5 | 6.25 | 3.12 | 1.56 | 0 |
| OD | 0.216 | 0.298 | 0.417 | 0.669 | 0.955 | 1.405 | 1.79 | 1.865 |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Mouse Folic Acid spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 81-101 | 96 |
| Plasma(n=8) | 92-105 | 101 |
| Cell Culture Supernates(n=8) | 97-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Mouse Folic Acid and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 83-95 | 88-96 | 90-110 |
| Average (%) | 91 | 92 | 96 | |
| 1 : 4 | Range (%) | 89-104 | 87-108 | 105-115 |
| Average (%) | 93 | 98 | 110 |
Size
Quantity
Price ($)
48T
1
360 / 360
96T
1
460 / 460