Product Name:
Human Beta-Endorphin (β-EP) ELISA Kit
Cat.#:
JL11415
Regulatory Status:
Alternative:
b-EP
Detection Method:
ELISA
Assay Type:
Competitive
Detection Range:
15.62-1000pg/mL
Sensitivity:
6.22pg/mL
Specificity:
This kit recognizes Human β-EP in samples. No significant cross-reactivity or interference between Human β-EP and analogues was observed.
Sample Type:
Serum;plasma;cerebrospinal fluid and other biological fluids
Assay Procedure:
Research Area:
Signal Transduction
Product Datasheets
| β-EP
β-Endorphin (beta-endorphin) is an endogenous opioid neuropeptide and peptide hormone that is produced in certain neurons within the central nervous system and peripheral nervous system.β-Endorphin is found in neurons of the hypothalamus, as well as the pituitary gland. It is derived from β-lipotropin, which is produced in the pituitary gland from a larger peptide precursor, proopiomelanocortin (POMC).POMC is cleaved into two neuropeptides, adrenocorticotropic hormone (ACTH) and β-lipotropin.The formation of β-endorphin is then the result of cleavage of the C-terminal region of β-lipotropin, producing a 31 amino acid-long neuropeptide with an alpha-helical secondary structure.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (pg/mL) | 1000 | 500 | 250 | 125 | 62.5 | 31.25 | 15.62 | 0 |
| OD | 0.216 | 0.298 | 0.417 | 0.669 | 0.955 | 1.405 | 1.79 | 1.865 |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human β-EP spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 81-101 | 96 |
| Plasma(n=8) | 92-105 | 101 |
| Linearity
Samples were spiked with high concentrations of Human β-EP and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | ||
| 1 : 2 | Range (%) | 83-95 | 88-96 |
| Average (%) | 91 | 93 | |
| 1 : 4 | Range (%) | 89-104 | 87-107 |
| Average (%) | 93 | 98 |
Size
Quantity
Price ($)
48T
1
360 / 360
96T
1
460 / 460


