Product Name:
Human Secretin (secretin) ELISA Kit
Cat.#:
JL11315
Regulatory Status:
Alternative:
secretin
Detection Method:
ELISA
Assay Type:
Competitive
Detection Range:
23.43-1500pg/mL
Sensitivity:
12.5pg/mL
Specificity:
This kit recognizes Human secretin in samples. No significant cross-reactivity or interference between Human secretin and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Research Area:
Metabolism
Product Datasheets
| secretin
Secretin is a hormone that regulates water homeostasis throughout the body and influences the environment of the duodenum by regulating secretions in the stomach, pancreas, and liver. It is a peptide hormone produced in the S cells of the duodenum, which are located in the intestinal glands.Secretin helps regulate the pH of the duodenum by inhibiting the secretion of gastric acid from the parietal cells of the stomach and stimulating the production of bicarbonate from the ductal cells of the pancreas.It also stimulates the secretion of bicarbonate and water by cholangiocytes in the bile duct, protecting it from bile acids by controlling the pH and promoting the flow in the duct.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (pg/mL) | 1500 | 750 | 375 | 187.5 | 93.75 | 46.87 | 23.43 | 0 |
| OD | 0.19 | 0.24 | 0.31 | 0.55 | 0.97 | 1.38 | 1.96 | 2.52 |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human secretin spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 81-101 | 96 |
| Plasma(n=8) | 92-105 | 101 |
| Cell Culture Supernates(n=8) | 97-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human secretin and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 83-95 | 88-96 | 90-110 |
| Average (%) | 91 | 93 | 96 | |
| 1 : 4 | Range (%) | 89-104 | 87-108 | 105-115 |
| Average (%) | 93 | 98 | 110 |
Size
Quantity
Price ($)
48T
1
360 / 360
96T
1
460 / 460


