400-0066-400

Human Endothelin 2 (ET-2) ELISA Kit

Home  >  Competitive ELISA Kits  >  Human Endothelin 2 (ET-2) ELISA Kit
Product Name:

Human Endothelin 2 (ET-2) ELISA Kit

Cat.#:

JL19688

Regulatory Status:
Alternative:

EDN2;ET2; PPET2; Preproendothelin-2

Detection Method:
ELISA
Assay Type:
Competitive
Detection Range:
15.6-1000pg/mL
Sensitivity:
7.5pg/mL
Specificity:
This kit recognizes Human ET-2 in samples. No significant cross-reactivity or interference between Human ET-2 and analogues was observed.
Sample Type:
Tissue homogenates;cell lysates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Signal Transduction
  • Human Endothelin 2 (ET-2) ELISA Kit
  • Human Endothelin 2 (ET-2) ELISA Kit
  • Human Endothelin 2 (ET-2) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| ET-2

Endothelin 2 (ET-2) belongs to a family of three endothelin peptide isoforms (ET-1, ET-2, ET-3), which constrict blood vessels. ET-2 is encoded by genes on separate chromosomes to its isoforms and is mainly produced in vascular endothelial cells of the kidney, placenta, uterus, heart, central nervous system and intestine.It becomes present in the blood of animals and humans at levels ranging from 0.3pg/ml to 3pg/ml.ET-2 acts by binding to two different G-protein coupled receptors (GPCRs), the endothelin A receptor (EDNRA) and the endothelin B receptor (EDNRB).
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (pg/mL) 1000 500 250 125 62.5 31.2 15.6 0
OD 0.14 0.23 0.41 0.67 0.85 1.14 1.45 1.79
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human ET-2 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 95
Plasma(n=8) 92-105 102





 

| Linearity

Samples were spiked with high concentrations of Human ET-2 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4)
1 : 2 Range (%) 84-96 88-96
Average (%) 91 93
1 : 4 Range (%) 89-103 87-108
Average (%) 94 98







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
360 / 360
96T
1
460 / 460
Top