400-0066-400

Human Relaxin 3 (RLN-3) ELISA Kit

Home  >  Competitive ELISA Kits  >  Human Relaxin 3 (RLN-3) ELISA Kit
Product Name:

Human Relaxin 3 (RLN-3) ELISA Kit

Cat.#:

JL34050

Regulatory Status:
Alternative:

ZINS4; RXN3; H3; INSL7; Insulin-like peptide 7; Prorelaxin H3

Detection Method:
ELISA
Assay Type:
Competitive
Detection Range:
31.2-2000pg/mL
Sensitivity:
15.9pg/mL
Specificity:
This kit recognizes Human RLN-3 in samples. No significant cross-reactivity or interference between Human RLN-3 and analogues was observed.
Sample Type:
Serum;plasma and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Signal Transduction
  • Human Relaxin 3 (RLN-3) ELISA Kit
  • Human Relaxin 3 (RLN-3) ELISA Kit
  • Human Relaxin 3 (RLN-3) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| RLN-3

Relaxin-3 is a neuropeptide and which is highly conserved in species ranging from flies, fish, rodents and humans.Relaxin-3 is a member and ancestral gene of the relaxin family of peptides, which includes the namesake hormone relaxin (designated 'H2 relaxin' in humans) which mediates peripheral actions during pregnancy and which was found to relax the pelvic ligament in guinea pigs almost a century ago. The cognate receptor for relaxin-3 is the G-protein coupled receptor RXFP3 (relaxin family peptide 3 receptor), however relaxin-3 is pharmacologically able to also cross react with RXFP1 and RXFP3.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (pg/mL) 2000 1000 500 250 125 62.5 31.2 0
OD 0.188 0.27 0.389 0.642 0.929 1.38 1.766 1.842
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human RLN-3 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 81-101 96
Plasma(n=8) 92-105 101





 

| Linearity

Samples were spiked with high concentrations of Human RLN-3 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4)
1 : 2 Range (%) 83-96 88-96
Average (%) 91 93
1 : 4 Range (%) 89-104 87-108
Average (%) 93 98







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
420 / 420
96T
1
640 / 640