Human Cortisol (Cortisol) ELISA Kit

Home  >  Competitive ELISA Kits  >  Human Cortisol (Cortisol) ELISA Kit
Product Name:

Human Cortisol (Cortisol) ELISA Kit

Cat.#:

JL12377

Regulatory Status:
Alternative:

Hydrocortisone

Detection Method:
ELISA
Assay Type:
Competitive
Detection Range:
0.312-20ng/mL
Sensitivity:
0.158ng/mL
Specificity:
This kit recognizes Human Cortisol in samples. No significant cross-reactivity or interference between Human Cortisol and analogues was observed.
Sample Type:
Serum;plasma;urine and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Metabolism
  • Human Cortisol (Cortisol) ELISA Kit
  • Human Cortisol (Cortisol) ELISA Kit
  • Human Cortisol (Cortisol) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| Cortisol

Cortisol is a steroid hormone in the glucocorticoid class of hormones and a stress hormone. When used as medication, it is known as hydrocortisone.It is produced in many animals, mainly by the zona fasciculata of the adrenal cortex in an adrenal gland.In other tissues, it is produced in lower quantities.By a diurnal cycle, cortisol is released and increases in response to stress and a low blood-glucose concentration.It functions to increase blood sugar through gluconeogenesis, suppress the immune system, and aid in the metabolism of calories.It also decreases bone formation.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 20 10 5 2.5 1.25 0.625 0.312 0
OD 0.19 0.24 0.31 0.55 0.97 1.38 1.96 2.52
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human Cortisol spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 81-102 97
Plasma(n=8) 92-105 101





 

| Linearity

Samples were spiked with high concentrations of Human Cortisol and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4)
1 : 2 Range (%) 83-95 88-96
Average (%) 91 93
1 : 4 Range (%) 88-105 87-108
Average (%) 93 98







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
360 / 360
96T
1
460 / 460