Product Name:
Human Enkephalin (ENK) ELISA Kit
Cat.#:
JL10976
Regulatory Status:
Alternative:
Enkephalin
Detection Method:
ELISA
Assay Type:
Competitive
Detection Range:
12.5-800pg/mL
Sensitivity:
6.5pg/mL
Specificity:
This kit recognizes Human ENK in samples. No significant cross-reactivity or interference between Human ENK and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Research Area:
Neuroscience
Product Datasheets
| ENK
An enkephalin is a pentapeptide involved in regulating nociception (pain sensation) in the body. The enkephalins are termed endogenous ligands, as they are internally derived (and therefore endogenous) and bind as ligands to the body's opioid receptors. Discovered in 1975, two forms of enkephalin have been found, one containing leucine, and the other containing methionine. Both are products of the proenkephalin gene.Enkephalin is also considered a neuropeptide, which in the human body performs as an important signaling molecule in the brain. Enkephalins are found in high concentration in the brain as well as in the cells of adrenal medulla. In response to pain, norepinephrine, a hormone that is activated in fight-or-flight response, is released along with endorphins.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (pg/mL) | 800 | 400 | 200 | 100 | 50 | 25 | 12.5 | 0 |
| OD | 0.188 | 0.27 | 0.389 | 0.642 | 0.929 | 1.38 | 1.766 | 1.842 |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human ENK spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 81-101 | 95 |
| Plasma(n=8) | 92-105 | 101 |
| Linearity
Samples were spiked with high concentrations of Human ENK and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | ||
| 1 : 2 | Range (%) | 83-95 | 88-96 |
| Average (%) | 91 | 93 | |
| 1 : 4 | Range (%) | 89-104 | 87-108 |
| Average (%) | 93 | 98 |
Size
Quantity
Price ($)
48T
1
360 / 360
96T
1
460 / 460