400-0066-400

Human Thromboxane B2 (TXB2) ELISA Kit

Home  >  Competitive ELISA Kits  >  Human Thromboxane B2 (TXB2) ELISA Kit
Product Name:

Human Thromboxane B2 (TXB2) ELISA Kit

Cat.#:

JL12478

Regulatory Status:
Alternative:

TX-B2

Detection Method:
ELISA
Assay Type:
Competitive
Detection Range:
23.43-1500pg/mL
Sensitivity:
10.08pg/mL
Specificity:
This kit recognizes Human TXB2 in samples. No significant cross-reactivity or interference between Human TXB2 and analogues was observed.
Sample Type:
Serum;plasma and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Cardiovascular Biology
  • Human Thromboxane B2 (TXB2) ELISA Kit
  • Human Thromboxane B2 (TXB2) ELISA Kit
  • Human Thromboxane B2 (TXB2) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| TXB2

Thromboxane B2 (TXB2) is an inactive metabolite/product of thromboxane A2. It is almost completely cleared in the urine.It itself is not involved in platelet activation and aggregation in case of a wound, but its precursor, thromboxane A2, is.2-(3,4-Di-hydroxyphenyl)-ethanol (DHPE) is a phenolic component of extra-virgin olive oil. An olive oil fraction containing DHPE can inhibit platelet aggregation and thromboxane B2 formation in vitro.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (pg/mL) 1500 750 375 187.5 93.75 46.87 23.43 0
OD 0.188 0.27 0.389 0.642 0.929 1.38 1.766 1.842
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human TXB2 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 81-101 96
Plasma(n=8) 92-105 101





 

| Linearity

Samples were spiked with high concentrations of Human TXB2 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4)
1 : 2 Range (%) 83-95 88-96
Average (%) 91 93
1 : 4 Range (%) 89-104 87-108
Average (%) 93 98







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
360 / 360
96T
1
460 / 460
Top